Salient Characteristics:001: Quaestor 8000 Standard: (R63260) Must be able to test Drager PSS 7000SCBA?s and Drager Pas-Colt Escape paks Must be a fully automatic test instrument for thetesting of full-face masks, compressed air breathing apparatus and closed-circuit breathingapparatus Must have training on new equipment provided by seller Must have an externalmicrophone Must have a gauge holder Must have a low-pressure measuring point Musthave a test head with gel face Must have a storage area for components Must have a CPSfilling connection Must have a medium pressure extractable inlet and a rotatable outletMust have a high-pressure inlet and outlet Must have a breathing volume of at least 134L/min The breathing frequency of the artificial lung must be at least 5 to 38 strokes a min.Must have a pressure sensor accuracy less than 1 according to DIN EN 837 Must havepermitted air pressure no less than 22 inHg and no more than 36 inHg Must weigh at least45 lbs. Must have a permitted low storage temperature of -20F and a permitted high storagetemperature of 136F Must have a high-pressure range of at least 350 bar Must have amedium pressure range of at least 25 bar Must have a low-pres...